Mitsubishi DSA series surge absorber
Number of Views:67122021-06-22 14:34:40
It can be widely used in low voltage and low current circuits such as communication equipment and sensor lines.
Small static capacity, can be used for signal line.
Dsa-a can be combined with varistor or specified ceramic resistor in various power supply circuits.
In the power supply circuit, the AC withstand voltage test can be carried out without removing the surge absorber.
(above 2400V)
Dsa-a type can be used as UL certified product when combined with UL certified varistor or designated ceramic resistor (rgbs5l-3wk)( Ul1449 Document No. e318314)
Shape | Model | DC discharge start voltage | Insulation resistance |
Electrostatic capacity 1kHz-6V max. |
Surge tolerance 8/20μsec. |
|
A-Type | DSA-301LA | 300V(255~345) | 100MΩ min. | DC100V | 2pF max. |
Wire diameter ø0.4mm :1500A Wire diameter ø0.5mm :2000A |
DSA-501MA | 500V(400~600) | DC250V | ||||
DSA-701MA | 700V(560~840) | |||||
DSA-102MA | 1,000V(800~1,200) | DC500V | ||||
DSA-152MA | 1,500V(1,200~1,800) | |||||
DSA-242MA | 2,400V(1,920~2,880) | |||||
DSA-282MA | 2,800V(2,240~3,360) | |||||
DSA-302MA | 3,000V(2,400~3,600) | |||||
DSA-332MA | 3,300V(2,640~3,960) | |||||
DSA-362MA | 3,600V(2,880~4,320) | |||||
DSA-402MA | 4,000V(3,200~4,800) | |||||
DSA-452MA | 4,500V(3,600~5,400) | DC1000V | ||||
DSA-622MA | 6,200V(4,960~7,440) | |||||
DSA-752MA | 7,500V(6,000~9,000) |
Shape | Model |
Surge life 8/20μsec. 100A |
AC withstand voltage | UL certified products |
CSA certification |
EN certification |
|
4) UL1449 |
5) UL497B |
6) LTI-002-2011 |
7) EN62368-1 |
||||
A-Type | DSA-301LA | 300times | - | ○1) | ○ | - | - |
DSA-501MA | - | ○1) | ○ | - | - | ||
DSA-701MA | - | ○1) | ○ | - | - | ||
DSA-102MA | - | ○1) | - | - | - | ||
DSA-152MA | - | ○1) | - | - | - | ||
DSA-242MA |
AC1,000V-1min. AC1,200V-3sec. |
○1) | - | ○2) | - | ||
DSA-282MA |
AC1,000V-1min. AC1,250V-3sec. |
○1) | - | ○2) | - | ||
DSA-302MA | AC1,500V-1min. | ○1) | - | ○2) | ○3) | ||
DSA-332MA | AC1,800V-3sec. | ○1) | - | ○2) | ○3) | ||
DSA-362MA | ○1) | - | ○2) | ○3) | |||
DSA-402MA | AC2,000V-1min. | ○1) | - | ○2) | ○3) | ||
DSA-452MA | AC2,000V-1min. | ○1) | - | ○2) | ○3) | ||
DSA-622MA | AC3,000V-3sec. | - | - | ○2) | ○3) | ||
DSA-752MA | AC3,600V-3sec. | - | - | ○2) | ○3) |
1): Compared with the ceramic resistor specified by our company (ac125 rgbs5l-3) Ω K) Or varistor (ac125v: v1ma ≥ 270V, D ≥) ø 5mm,AC250V:V1mA≥470V,D≥ ø 5mm) electrical series connection (wire winding, crimping, welding, etc.) Be certified. 2): And varistor (ac125v: v1ma ≥ 270V, D ≥) ø 5mm,AC250V:V1mA≥470V,D≥ ø 5mm) electrical series connection (wire winding, crimping, welding, etc.) can be certified. 3): And varistor (v1ma ≥ 470v, D ≥) ø 10 mm) electrical series connection (wire winding, crimping, welding) can be certified. 4): UL Standard UL 1449 File No. E318314 5): UL Standard UL497B File No. E175280 DC spark-over voltage is described as break down voltage in the UL report. 6): CSA Standard LTI-002-2011 File No. CA111411 7): T Ü V Report No. J9851289(DSA-752MA), J9251508(Others) |
|
Contact us
Dongguan Jingpin Electronic Technology Co., Ltd
Tel:086-769-88761999
Fax:086-769-88770899
Email:sales@jpet.cn
Address: 8F, building F1, Tianan Digital City, No.1, Huangjin Road, Nancheng District, Dongguan City
Copyright 2020 Dongguan Jingpin Electronic Technology Co., Ltd copyright All Rights Reserved
Website filing:粤ICP备10083821号