bet5365亚洲版-首页

浪涌吸收器
Surge absorber
Current location:

Mitsubishi DE37 series surge absorber

Number of Views:60672021-06-23 12:00:25



Mitsubishi DE37 series surge absorber

Features:  

●Using a radial taping shape with a 5mm lead pitch, suitable for automatic insertion (the height of the component is controlled below 15.5mm). (Except for varieties above 2700V)
●Axial braid can be selected (automatic insertion can also be realized when the glass discharge tube is placed flat).
●The low electrostatic capacitance below 1pF will not hinder the megabit-level high-speed communication signal.
●Using micro-gap method, has excellent surge response effect.
●It has high insulation resistance characteristics above 100MΩ.

Size:

 

Electrical characteristics:

Model DC discharge start voltage
(Vs)
Insulation resistance
(IR)
Electrostatic capacity
1kHz-6V max
Surge tolerance
8/20μsec.
DE37-301L 300V(255~345) 100MΩmin. DC 100V 1pF max 1500A
DE37-351M 350V(280~420) DC 250V
DE37-401W 400V(340~480)
DE37-501M 500V(400~600)
DE37-102M 1,000V (800~1,200) DC 500V
DE37-272M 2,700V (2,160~3,240)
DE37-302M 3,000V (2,400~3,600)
DE37-362M 3,600V (2,880~4,320)
DE37-452M 4,500V (3,600~5,400) DC 1000V
Model Surge life
8/20μsec
AC withstand voltage UL certified products EN standard certified products
4)
UL497B
5)
UL1449
6)
EN62368-1
DE37-301L 100A 300times - - -
DE37-351M - - -
DE37-401W - - -
DE37-501M - - -
DE37-102M - - - -
DE37-272M 100A 200times AC1,000V-1min.
AC1,200V-3sec.
- ○ 1) -
DE37-302M AC1,500V-1min. - ○ 2) ○ 3)
DE37-362M AC1,800V-3sec. - ○ 2) ○ 3)
DE37-452M AC2,000V-1min. - ○ 2) ○ 3)
1): It will be approved if it is electrically connected in series with a varistor (AC125V: V1mA≥270V, D≥5mm) (wire winding, crimping, welding, etc.).
2): If it is electrically connected in series (wire winding, crimping, welding, etc.) with a varistor (AC125V: V1mA≥270V, D≥5mm, AC250V: V1mA≥470V, D≥5mm), it will be approved.
3): It will be approved if it is electrically connected in series with a varistor (V1mA≥470V, D≥5mm) (wire winding, crimping, welding).
4): UL Standard UL 497B File No. E175280 DC spark-over voltage is described as break down voltage in the UL report.
5): UL Standard UL 1449 File No. E318314
6): TÜV Report No.J50164439

ITU-T K.20 Basic Test Condition(Basic test conditions)

•Surge test
10/700 msec 1.5kV/4kV(25Ω)±5 times
•AC induction test
AC600V(600Ω)1sec. 5 times
•AC crossover test
AC230V (10-1000Ω) 15min
But when AC230V is applied, DE37-401W does not respond.

Contact us

Dongguan Jingpin Electronic Technology Co., Ltd

Tel:086-769-88761999

Fax:086-769-88770899

Email:sales@jpet.cn

Address: 8F, building F1, Tianan Digital City, No.1, Huangjin Road, Nancheng District, Dongguan City

Copyright 2020 Dongguan Jingpin Electronic Technology Co., Ltd copyright All Rights Reserved

Website filing:粤ICP备10083821号

Baidu
sogou